Files
Last update 1 day 6 hours
by
Fabian
SW Phases.mdTODO subject to review:
1. HS Turns on
- LS reverse recovery (C_rr discharges)
- ringing switch-node
- LS self turn on
- HS miller effect
2. HS Turns off and LS body diode turns on
- Vsw falls from Vi to -1V (LS body diode Vsd)
- LS Coss discharged, mosfet releases energy (-3.3913µJ)
- LS body diode power ups (C_rr charges)
- Vsw is now 1V below ground
3. LS Turns on
- Vsw goes from -1V to GND
- Current spike in LS drain and HS drain
4. LS Turns off
- Vsw GND -> -1V
- C_rr charged
AUIRFS/SL4115