Files

copied
Last update 7 years 2 weeks by DangKhanhNguyen
Files1. Schematicallegro
..
netlist.log
pxlBA.txt
pxlBA.txt
# pxlba generated file # pxlBA.txt : Extract file used to extract properties for # back annotation using packagerxl. Refer to Allegro extract # documentation for more details on the syntax of this file # and the Extract program. # The lines starting with # are comments. # The default version of this file extracts the minimum number # of properties necessary to ba changes to packaging. # To extract additional properties the user must remove the # comment character '#' from the appropriate lines. Or # add a line with the property name to the appropriate section. # a2pxl looks for this file in the current working directory. # If it is not found there, it looks for it # in the hierarchy in the following location: # <installation dir>/tools/pcb/text/views # Connection view. File: pinView.dat # LOGICAL_PIN # These properties must not be removed, moved or modified. # vvvvvvvvvvvvvvvvvvv NET_NAME REFDES PIN_NUMBER FUNC_LOGICAL_PATH COMP_DEVICE_TYPE FUNC_SCH_SIZE FUNC_HAS_FIXED_SIZE FUNC_DES # ^^^^^^^^^^^^^^^^^^^ # Any other PIN properties to be back annotated show up here. PIN_NET_SHORT PIN_NO_SWAP_PIN PIN_NO_PIN_ESCAPE PIN_PIN_ESCAPE PIN_PIN_SIGNAL_MODEL PIN_NO_DRC PIN_NO_SHAPE_CONNECT END # Function properties view. File: funcView.dat # In order to backannotate function properties you must # include FUNC_LOGICAL_PATH. # FUNCTION FUNC_LOGICAL_PATH COMP_DEVICE_TYPE REFDES FUNC_PRIM_FILE COMP_PARENT_PPT COMP_PARENT_PPT_PART COMP_PARENT_PART_TYPE FUNC_SCH_SIZE FUNC_HAS_FIXED_SIZE FUNC_DES FUNC_GROUP FUNC_ROOM FUNC_CDS_FSP_UID FUNC_NO_SWAP_PIN FUNC_HARD_LOCATION FUNC_NO_SWAP_GATE_EXT FUNC_CDS_FSP_MAPPED_CELL FUNC_CDS_FSP_FPGA_SYMBOL FUNC_CDS_FSP_TERM_TYPE FUNC_CDS_FSP_TERM_NAME FUNC_ROOM FUNC_GROUP FUNC_CDS_FSP_TERM_INDEX FUNC_NO_SWAP_GATE END # Component properties view. File: compView.dat # In order to backannotate component properties you must # include REFDES # COMPONENT REFDES COMP_VOLTAGE COMP_CDS_FSP_LIB_PART_MODEL COMP_CDS_FSP_INSTANCE_NAME COMP_ROOM COMP_GROUP COMP_SIGNAL_MODEL COMP_CDS_FSP_INSTANCE_ID COMP_NO_XNET_CONNECTION COMP_CDS_FSP_IS_FPGA # The following two properties are needed to feedback ppt # part selections done in Allegro. # You may comment them out if you do not use this functionality. COMP_PARENT_PPT COMP_PARENT_PPT_PART COMP_REUSE_ID COMP_REUSE_NAME COMP_REUSE_INSTANCE END # # Signal properties view. File: netView.dat # In order to backannotate signal properties you must # include NET_NAME # NET NET_NAME NET_LOGICAL_PATH NET_CDS_FSP_UID NET_SHIELD_NET NET_RELATIVE_PROPAGATION_DELAY NET_NO_PIN_ESCAPE NET_NET_SHORT NET_VOLTAGE_LAYER NET_VOLTAGE NET_RATSNEST_SCHEDULE NET_CLOCK_NET NET_NET_PHYSICAL_TYPE NET_MAX_FINAL_SETTLE NET_NO_TEST NET_MAX_EXPOSED_LENGTH NET_ELECTRICAL_CONSTRAINT_SET NET_CDS_FSP_BUS_INDEX NET_STUB_LENGTH NET_SHIELD_TYPE NET_NO_RAT NET_PROPAGATION_DELAY NET_NO_RIPUP NET_MIN_HOLD NET_DIFFERENTIAL_PAIR NET_MIN_SETUP NET_MIN_NECK_WIDTH NET_BUS_NAME NET_MIN_NOISE_MARGIN NET_MATCHED_DELAY NET_ECL NET_DIFFP_LENGTH_TOL NET_DIFFP_2ND_LENGTH NET_NET_GROUP_GRP_NAME NET_SUBNET_NAME NET_MIN_BOND_LENGTH NET_MAX_OVERSHOOT NET_TS_ALLOWED NET_MAX_VIA_COUNT NET_EMC_CRITICAL_NET NET_CDS_FSP_NET NET_PROBE_NUMBER NET_NO_ROUTE NET_MIN_LINE_WIDTH NET_ECL_TEMP NET_NO_GLOSS NET_ROUTE_PRIORITY NET_NET_SPACING_TYPE NET_IMPEDANCE_RULE END
Report a bug