T184.mdKS184-125A, 1.8mm? (Cu? dark), 2 strands, 15 turns
- Power measurement: - V=73/28.5, I=29.7A, Ipp=18A - Ploss = -4.4784 std= 0.1549
Mod: added 2 turns (17 now): - Power measurement - I=30.7A Ipp=16.7 (!) - Ploss= -3.7764 std= 0.2066
KS184-125A, 1.8mm? (Cu?), 2 strands
- the coil design is not ideal
- core saturates early (u=125)
- has losses also during light load
due to many turns, the magnetic field is even higher, core saturates
Power measurement:
- V=73/28.5, I=29.7A, Ipp=13A
- Ploss = 10.6W +- 0.2W
KS184-075A, 2.5mm CuW210, 2 strands, 17 turns
KS184-075A-CuW210-d2.5-s2-t17
- 2.5mm is AWG10.3
- had 3m of wire total (1.5m per strand)
- could not fit more than 17 turns
- excess 50cm
- core KS184-075A datasheet https://semic.cz/!old/files/pdf_www/Ljf_T184-S-075A_KD.pdf
- computed L0 = 48.8uH (core Al=169)
- micrometals analyzer:
- ID ratio 0.35, which is completely off
- 40khz, 30A: Ldc is 30-32, Ipp 12-14A, 4.8W Total loss, 2.76W copper loss
- Rdc = 2.7mΩ, Rac factor = 7.731
consider using KS184-090A
Power measurement:
- V=73/28, I=30A, Ipp=14A
- Ploss = Total Mean -5.8W std= 0.3 TODO propably wrong
hf-litz
Core: KS185-075A Coil: 32strands Wire: 0.5mm wire (schneitech) AWG#24.1 or AWG#24.2 OD (with varnish): 0.545 mm .. 0.566 mm Nennwiderstand bei 20°C: 0,0871 Ω/m (Gewicht - nur Kupferleiter ohne Lack - 8,96kg/dm³: 1,7593 kg/km)
Micrometals Analyzer: L0 = 102.46 Ldc(30A) = 46.18 (45%) Rdc = 0.006624 ID use ratio = 0.56 ploss(30A,27/45V,39khz) = 7.1 W (cu 6.105W)
Power Meausre: Vin 72/28 I=29.4A, Ipp=8.08A Vin 70/26.2 I=15.8 Ipp=4.73 => L = 89.5uH Vin 69/26.9 I=23.2A Ipp=6.3A => L= 67.7uH 68.2/27 i=33.6 ipp=9.33 => L= 44.8uH 73.5/27.2 i=27.5 ipp=8A => L= ? TODO i=33i=9.55
-> micrometals analyzer says 26 turns on their MS-184075-2 (same nom. Al=169nH) inside a little paper box temperature rise is 35°C.
about 360cm total wire length pre-winding excess after winding: 34+77 bonding wires: ? total wound length: ? forgot the count number of turns
termination get a tool to remove the varnish a good way seems to create bundles of 5
Rdc (4wire, keithley): 6.76mΩ micrometals analyzer
TODO: - measure Rdc - measure L0 - use thermal imager to check strands
2s KS184-125A
- coil: w210 cu, 1.18mm, 12 strands (used 2m wire per strand)
- 10 turns?
- Measurement :
- Vin 73.2/27.2, I=15.8A, Ipp=9.3A
- 76/27 I=0, ipp=7
- 73.5/27.3 I=34.3 Ipp=14.6A
- 72.3/27.3 i=36.9 Ipp=15.6A
2s KS184-125A-d1.18-s10-n12
- coil: w210 cu, 1.18mm (schneitec), 10 strands (used 2m wire per strand) - 12 turns? - Rdc(keithley, 4wire clamps) = 2.43mΩ - Measurements: - 73.3/27.3 I=30.4 Ipp=12.2A
TODO: 8 strands, 15 turns
Codacoa
- in boost converter
- I=31A, Ipp = 14.8A
- Ploss = 4.9W std=0.33
- Power Measurements
- 26/73V I=35.5A ipp=15A