fabrication output
by Arnaud Mercier 2 years 1 month
changed ADA4841 footprint
by Arnaud Mercier 2 years 1 month
Changed the board outline The board outline was changed to be exactly 115 mm x 32 mm. Other boards will be standardised to 32 mm width
by Christian Dupuis 2 years 1 month
Upgraded nano-fit connector (1x07) Changed the RS485 BUS connector (molex nano-fit) from 1x05 to 1x07 to make it easier to daisy chain the boards together
by Christian Dupuis 2 years 1 month
Fixed DRC violations Fixed DRC violations based on missing footprints. Should review THVD8000 foot print as it had to be changed from 'missing' footprint import. This version passes all DRC checks. Net clearance was changed to 0.127 mm (4mill) otherwise the SOT-23 pads were failling DRC
by Christian Dupuis 2 years 1 month
Changed worker board layout V2 Removed micro-vias, used only two layers, changed connectors and generally re-worked the worker board
by Christian Dupuis 2 years 1 month
Change footprint of the single header connector
by Arnaud Mercier 2 years 4 months
DRC clean Remove the warning by repositioning the label on both top and bottom layer Replace the +5V net for the 5V net
by Arnaud Mercier 2 years 5 months
Replace label in only 2 dimensions and without overlaping on traacks
by Arnaud Mercier 2 years 5 months
updated the teensy symbol witht he G2 pin The G2 pin can now be connected to GND directly in the pcb without the need of a via
by Arnaud Mercier 2 years 5 months
Report a bug