[IMP] hardware: v1.5 Minor Updates * Update Silkscreen * Move I-Bus trace further from board edge
by t3ddftw 4 years 6 months
1dd41ef1
[IMP] hardware: v1.5 Minor Updates * Update part numbers for several components * Update Silkscreen
by t3ddftw 4 years 6 months
134936f2
[IMP] hardware: v1.5 High Voltage improvements * Remove XRP6759 * Remove Old Tantalum C1 * Remove V1 * Remove L1 * Add common mode choke at input (L1) to filter out A/C * Add new Aluminum Polymer input Capacitor rated for 35v (40v transcients) (C1) * Add MPQ4420 wide input voltage switching regulator for 12v -> 5v regulation * Add XC6702 to protect Q2 from trancients and provide a constant voltage to TEL ON and Microphone power * Power Microphone through 12v rail * Rewire 3.3v net * Rewire 5v net * Fix decoupling cap positioning for PIC24 * Fix decoupling cap positioning for FT232RL
by t3ddftw 4 years 6 months
6c4dcb5a
[IMP] firmware: bootloader * Update to MPLAB X 5.35
by t3ddftw 4 years 6 months
e54cb7da
[IMP] firmware: Application 1.1.16 [Handler] * Fix bug where volume changes outside of a call impacted the call volume offset * Set maximum volume offset for calls to 30 steps * Fix bug where call status was not correctly set all the time * Improve caller ID * Report CD 7 for MID / CD53 UIs so that all 1-6 button presses result in a disc change event from the radio [MID UI] * Prevent screen refresh every ten seconds by responding wit the Everest TCU signature to `0x02` * Add metadata off mode * Add "Mode" button to BlueBus UI [CD53 UI] * Add newer CD53 (E8x) support by listening to telephone events and responding to them [Upgrade] * Add batch three cVc license [Misc] * Update defines for events * Update to MPLAB X 5.35 * Remove PLLCLK register settings for WM8804
by t3ddftw 4 years 6 months
f643253b
[IMP] utility: Improve Platform Request Code * Try to pull the platform five times before giving up
by t3ddftw 4 years 6 months
d191b15f
[FIX] application: Fix central lock status identification
by t3ddftw 4 years 6 months
6d62f67f
Add hyphen and ellipsis UTF-8 characters
by Christian Hack 4 years 7 months
9f991b80
[FIX] firmware: Application cleanup * Update BC127 definition verbiage * Fix possible memory leak in BMBT device name handler
by t3ddftw 4 years 7 months
ea489334
[IMP] firmware: Application Comfort Blinker Enhancements * Activate comfort blinkers only after single blink/off cycle. * Allow cancelling comfort blinkers via opposing blink. * Deactivate comfort blinkers prior to activating opposing comfort blinkers to prevent the original switch input from becoming unresponsive. * Filter concurrent non-blinker lamp events during comfort blinking to prevent artificially incrementing blinker count. * Stop comfort blinkers via diagnostic activation, rather than diagnostic end. * All LM variants now support diagnostic blinker deactivation.
by Piers Holt 4 years 7 months
9824bc4c
Report a bug