[IMP] firmware: bootloader
* Update to MPLAB X 5.35
by
t3ddftw
4 years 6 months
[IMP] firmware: Application 1.1.16
[Handler]
* Fix bug where volume changes outside of a call impacted the call volume offset
* Set maximum volume offset for calls to 30 steps
* Fix bug where call status was not correctly set all the time
* Improve caller ID
* Report CD 7 for MID / CD53 UIs so that all 1-6 button presses result in a disc change event from the radio
[MID UI]
* Prevent screen refresh every ten seconds by responding wit the Everest TCU signature to `0x02`
* Add metadata off mode
* Add "Mode" button to BlueBus UI
[CD53 UI]
* Add newer CD53 (E8x) support by listening to telephone events and responding to them
[Upgrade]
* Add batch three cVc license
[Misc]
* Update defines for events
* Update to MPLAB X 5.35
* Remove PLLCLK register settings for WM8804
by
t3ddftw
4 years 6 months
[IMP] utility: Improve Platform Request Code
* Try to pull the platform five times before giving up
by
t3ddftw
4 years 6 months
[FIX] application: Fix central lock status identification
by
t3ddftw
4 years 6 months
[FIX] firmware: Application cleanup
* Update BC127 definition verbiage
* Fix possible memory leak in BMBT device name handler
by
t3ddftw
4 years 7 months
[IMP] firmware: Application Comfort Blinker Enhancements
* Activate comfort blinkers only after single blink/off cycle.
* Allow cancelling comfort blinkers via opposing blink.
* Deactivate comfort blinkers prior to activating opposing comfort blinkers to prevent the original switch input from becoming unresponsive.
* Filter concurrent non-blinker lamp events during comfort blinking to prevent artificially incrementing blinker count.
* Stop comfort blinkers via diagnostic activation, rather than diagnostic end.
* All LM variants now support diagnostic blinker deactivation.
by
Piers Holt
4 years 7 months
[IMP] firmware: Cyrillic Translitteration updates
* Additional Cyrillic characters added to mapping table
* Improve Extended ASCII character conversion
by
t3ddftw
4 years 7 months
[IMP] firmware: Application Improvements
* Add caller ID support
* Add caller ID to Navigation Incoming Call screen
* Improve VIN recognition logging
* Improve LM Identification
* Fix I2C implementation bug which prevented a dirty bus from being cleared
* Improve MID UI by hijacking TEL MID Mode
* Break out PCM51XX start up by shutting down the DAC, then starting it when required
* Improve String Normalization / UTF-8 translitteration
* Fix CD53 Device Selection
by
t3ddftw
4 years 7 months