Optimized size and solderability
by antscience 6 years 10 months
962871a9
Size and DRC Optimizations
by antscience 6 years 10 months
Size and DRC Optimizations

Final size: 1.5"x2.5". Might be a little tricky to solder now, but oh well
aa7c6ca8
ERC Compliant
by antscience 6 years 10 months
4463cee0
Version 2 Board File
by antscience 6 years 10 months
Version 2 Board File

Added in board file. FINAL
41b3aac2
Fixed ERC
by antscience 6 years 10 months
Fixed ERC

Went through ERC and fixed/approved all errors/warnings except for continuity ones. Board needs to be redrawn completely
4ba8fc51
Added SD Card
by antscience 6 years 10 months
Added SD Card

Forgot to add bypass cap to the SD card reader
98945fbb
Added SD Card reader
by antscience 6 years 10 months
Added SD Card reader

TODO: Verify if we need to use 3V3 or 5V for the SD card. If it's 3V, then we need to add in a level shifter between ATMEGA and the card.
cdf3f896
Version 2_UPDATED_ADC
by antscience 6 years 10 months
Version 2_UPDATED_ADC

Added in voltage regulators, power and programming headers, and bypass capacitors
TODO: Still need to add in SD card reader circuitry.

CHECK: Do we need to set AGND on the ADC to the sensor ground? Is the 0.5V regulator going to produce a steady reference voltage? What is the voltage for the strain gauges (UPDATE R2 VALUE WHEN WE KNOW)?
de4df6a6
New board with updated ADC1256 from TI
by antscience 6 years 10 months
New board with updated ADC1256 from TI

TODO: Redo calibration circuitry to be single-pot per bridge (REMOVE 1 pot chip), and add in 370 and 5k resistors as done in previous board versions
TODO: Add in programming header, SD card reader, and voltage regulators.
1fc49da1
Version 1 FINAL
by antscience 6 years 10 months
Version 1 FINAL

Nearly complete version of the first iteration of the strain gauge logger.
TODO: Check SD card for validity. I have no idea how it's supposed to be hooked up.
7810762d
Report a bug